How should I ground the Bobcat 250 when mounting it on a vehicle or trailer?
Connect a grounding cable from the equipment grounding terminal on the front panel to the metal vehicle frame using #10 AWG or larger insulated copper wire. You must also electrically bond the generator frame to the vehicle frame by metal-to-metal contact, as bed liners, shipping skids, and some running gears can insulate the generator from the vehicle frame. (Page 17)
From the official Miller Bobcat 250 Portable Welder Generator manual, page 17