The relief valve is factory set at 60 psi (414 kPa) and normally needs no adjustment—only adjust if replacing the motor. Connect a pressure gauge to the Coolant Out fitting and block or plug any output fitting on the gauge. Turn on power and adjust the pressure adjustment screw as needed. Turn off power, disconnect the gauge, and reinstall the nut.