How do I safely connect weld cables on the Deltaweld 302?
Turn off power, remove the supplied nut from weld output terminal, slide weld cable terminal onto the terminal and secure with nut so that it is tight against copper bar. Ensure no foreign objects are between terminals and surfaces are clean to avoid excessive heat or damage.
From the official Miller Deltaweld 302 manual, page 28