What is the maximum open-circuit voltage (OCV) for the Dynasty 350?
The maximum open-circuit voltage is 75 volts under normal conditions when in Stick mode with normal open-circuit voltage selected. However, the unit has a low open-circuit voltage mode of 10-15 volts available while in TIG Lift Arc or while in Stick with low open-circuit voltage selected. The rated peak striking voltage for arc starting is 15 kV.
From the official Miller Dynasty 350 manual, page 12
Have a follow-up question?
Answers from the official manual.
Common questions