How do I change the wire feed speed display from inches per minute (IPM) to meters per minute (MPM)?
Turn off the welding power source, disconnect input power, and check voltage on input capacitors before proceeding. Remove the feeder wrapper, then move the number 1 switch (top switch) on the Operator Interface Board dip switch to the ON position using a small screwdriver if necessary. Reinstall the wrapper after making the change. (Page 17)
From the official Miller PipeWorx 400 Welding Machine manual, page 17