What are the first steps to set up my Miller PipeWorx 400 when I first receive it?

Place the Pipeworx 400 on a stable, level surface and ensure adequate ventilation around the machine. Connect the input power cables to the appropriate power source according to your machine's voltage rating (230/460V or 575V), adhering to local electrical codes. Then attach the work cable to your workpiece using the EG500 clamp and connect your electrode holder or MIG gun to the appropriate output terminal.