What is required for testing the inlet gas pressure post-installation?

Shut off the manual valve, attach a manometer to measure and check the inlet gas pressure. Required range: NG (3.5"~10.5" WC) LP (8.0"~13.5" WC). Adjust as necessary with regulator.