How do I set the operating temperature for the ProBlue 10 tank, hoses, and guns?
Switch the melter on and access the Setup mode through the control panel. Use the numeric keypad to navigate to the temperature set-point parameters for the tank and each hose/gun module. Enter the desired set-point temperature for each component. The melter will maintain heated components at their assigned set-point temperatures and will generate an over-temperature fault if any component exceeds its set-point by more than the Over Temperature Delta (default 15°C/25°F) or an under-temperature fault if it drops below by more than the Under Temperature Delta (default 25°C/50°F).