What maintenance is required for the ProBlue 10?

Regular maintenance includes: relieving system pressure before servicing, monitoring and replacing the filter (the service LED indicates when maintenance is needed based on the Service Interval Time parameter, default 500 hours), cleaning the melter, cleaning the tank, and performing general inspections. Before maintenance, always de-energize the system and lock out external communications to prevent accidental activation.