Remotes Error Codes

24 error codes across 1 brands. Find your code, what it means, and how to fix it.

GE

24 codes
e1

High pressure sensor error identified via faulty AD sampling circuitry readings indicating failure in maintaining specified ranges during regular detection sequences.

E3

Compressor low pressure protection.

E4

Compressor discharge high temperature protection.

ee

Memory chip error detected indicating absence of proper initialization sequence upon power delivery preventing drive boards from recognizing essential memory storage devices for functioning.

F2

Condenser temperature sensor error detected.

F3

Outdoor ambient temperature sensor error detected.

F4

Discharge temperature sensor malfunction detected.

F6

ODU tube temperature sensor error detected.

H4

Overload protection triggered due to high condensing pressures.

H5

IPM module malfunction reported; drive processor supply voltage too low for proper operation.

H6

Main control unit failure in receiving valid signal from outdoor fan motor after start-up sequence initiated for at least 30 seconds.

H7

Processor cannot identify compressor rotor position correctly due to abnormal signal or phase connections leading to operation mismatch between expected vs operational speeds.

HC

Protection engaged due to PFC module malfunction causing a drop in system voltage below operable levels for normal operations.

LC

System failed to initiate at start-up stage indicating issues with compressor startup signals received via board LED display.

P0

Drive chip resets within initial moments of power-up leading to incomplete start cycle before detecting further errors necessitating a protective shutdown state.

P5

System protection triggered due to excessive current draw from compressor exceeding preset safety thresholds during high frequency/high load conditions.

P6

Master control fails to establish stable communication with drive module via electronic interface exceeding a set period threshold beyond which it enacts safety protocol.

P7

Temperature sensor error detected on IPM or PFC modules when temperature falls below established safety operating ranges.

P8

High temperature readings recorded on IPM or PFC modules activating protective mechanisms to maintain safe operational limits per design specifications of the equipment.

PA

System shutdown initiated in response to AC input current exceeding designated safety limits under operationally heavy conditions or abnormal grid voltage fluctuations affecting system stability.

Pc

Error indicating fault within the current detection circuitry after charge initialization period where signal distortions exceed threshold levels leading to protection protocol activation.

PH

System shutdown triggered by excessive busbar voltage reads surpassing safety specifications during normal operating phases indicative of severe electrical anomalies disrupting stable functioning.

PL

Protection enacted in response to busbar voltage dropping below safety thresholds during periods of normal operational state indicating system instability due to supply inadequacies.

PU

Charge loop malfunctions indicated by inability of busbar voltage to achieve target settings within stipulated timeframe following initialization phase triggering protective protocols.