error Upgraded

Error Code OC

Over Current alarm — the charging current exceeds 45 A, exceeding the controller's maximum current rating.

? What Causes This

Solar array short circuit current exceeds 30 A, or fault in the charging circuit causing excessive current flow.

How to Fix It

  1. Disconnect the solar array immediately.
  2. Check solar array connections for shorts or faults.
  3. Verify the solar array short circuit current (Isc) is less than 30 A.
  4. Check all wiring connections for damage or improper installation.
  5. If problem persists, the controller may be damaged and require service.

Source: page 45 of the official manual

From the manual

Manual page 45 — Upgraded error OC

This error code appears in:

Upgraded 30A Solar Charge Controller