error Yaskawa

Error Code LSO

Low speed motor step-out detected — indicates a problem with motor movement at low speeds.

? What Causes This

Improperly configured motor code, load is too heavy, external force on the load side causing movement, incorrect detection of motor magnetic pole position by drive, n8-84 (Initial Polarity Estimation Timeout Current) value is too low, incorrect settings in L8-93 to L8-95.

How to Fix It

- Ensure correct motor code configuration - Decrease the load weight and replace with a larger capacity model if needed - Repair external issues causing uncontrolled movement on the load side - Set b3-01 = 1 [Speed Search at Start Selection] to aid in proper pole detection - Increase n8-84 setting and consult motor manufacturer for max values - Adjust settings in L8-93 to L8-95 as needed

Source: page 2 of the official manual

From the manual

Manual page 2 — Yaskawa error LSO

This error code appears in:

Yaskawa Ga800 Variable Speed Drive