How long must I wait after turning off the Dynasty 280 before touching internal components?
You must wait at least 60 seconds after turning off the unit before working on internal components, because a dangerous DC voltage remains present in the input capacitors after shutdown. Alternatively, measure the voltage across the capacitors and confirm it is near zero (0V) before touching any internal components. Never touch charged capacitors.