How long should I wait before touching internal components after turning the Dynasty 280 off?
You must wait at least 60 seconds after turning off the unit before touching any internal components, because dangerous DC voltage remains present in the input capacitors after shutdown. Alternatively, you can measure the voltage on the capacitors and confirm it is essentially zero (0V) before making contact with any component. Never touch charged capacitors. (Page 9)