What fuse size is recommended for the Dynasty 280 running on 230V single-phase power?
For 230V single-phase operation at 100% duty cycle, the Dynasty 280 draws 53 amperes and the recommended maximum fuse rating is 60A for time-delay (retarded) fuses or 80A for standard (normal operation) fuses. The minimum input conductor size is AWG 10. The maximum recommended input conductor length at 230V single-phase is 55 feet (17 meters). (Page 20)
From the official Miller Dynasty 280 manual, page 20