How do I check for voltage on capacitors after removal of input power?
Before touching any internal components, verify that input capacitors have been discharged following instructions in the Maintenance Section. Use a multimeter to measure input capacitor voltage as per Section 9-7 (Page 48).
From the official Miller ProHeat 35 Industrial Heater manual, page 48