How do I perform a Pressure Relief Procedure on the XP Proportioner?

To relieve pressure, engage the gun trigger lock, close the main air shutoff valve (MA) for XP Proportioners or set the pump valve off for XP-h Proportioners, then shut off heaters and feed pumps. Remove the spray tip, disengage the trigger lock, and hold a metal part of the gun firmly to a grounded metal pail and trigger the gun to relieve pressure. Then close the dual shutoff handle (FE) and open the circulation handle (FC) to relieve A and B fluid pressure. Always flush the mix hose after relieving fluid pressure. (Page 29)

From the official Graco Tranzitions XP Proportioner manual, page 29