What precautions must be taken when working with isocyanates (ISO) to prevent moisture contamination?

Always use a sealed container with a desiccant dryer in the vent, or a nitrogen atmosphere, and never store ISO in an open container. Keep the ISO pump wet cup or reservoir filled with appropriate lubricant to create a barrier between the ISO and the atmosphere, and use only moisture-proof hoses compatible with ISO. Never use reclaimed solvents, which may contain moisture, and always keep solvent containers closed when not in use. (Page 7)

From the official Graco Tranzitions XP Proportioner manual, page 7